Integrated RMA with FMECA analysis using a graphical inteface: case study recycling isobutane pump (CP2K)

dc.contributor.authorMechhoud El-Arkam
dc.contributor.authorZennir Youcef
dc.date.accessioned2024-05-23T09:46:34Z
dc.date.available2024-05-23T09:46:34Z
dc.date.issued2020-03-01
dc.description.abstractThe objective of our work is the implementation of a new approach for the dependability enhancement of a recycling iso-butane pump (Skikda CP2K petrochemical plant) based on automated dependability analysis system including the automation of the RMA (Reliability, Maintainability, Availability) study and FMECA (Failure Mode Effect and Criticality Analysis) method. After the system description, we present briefly the principle of the automated method. The system analysis in degraded mode is realized by using FMECA method. This automated analysis brings out the different failure modes, their causes and their consequences of each component. The result is risks minimization and reliability enhancement of the considered system.
dc.identifier.issn2543-3792
dc.identifier.urihttp://dspace.univ-skikda.dz:4000/handle/123456789/1842
dc.language.isoen
dc.publisherALGERIAN JOURNAL OF SIGNALS AND SYSTEMS (AJSS).Vol. 5, Issue 1.pp 53-57
dc.titleIntegrated RMA with FMECA analysis using a graphical inteface: case study recycling isobutane pump (CP2K)
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Integrated RMA with FMECA.pdf
Size:
485.14 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: